Product Specifications |
Battery of Analyzer |
Battery
Backup Time (continuous duty) |
24
hours |
Low Battery indication |
Yes |
Chemistry of Rechargeable Battery |
Li-ion |
Number of Spare Rechargeable Batteries
supplied with the instrument |
0 |
Battery Voltage |
7.4
Volt |
Power Source |
Rechargeable
Battery |
Battery is BIS Approved |
Yes |
BIS Registration number for Battery under CRS
of Meaty |
R-91007129 |
Display /
Indicator / Storage / Interface |
Display
Type |
LCD |
Record Memory (Minimum) |
50000 |
Display Size |
5
inches |
If yes, Capable to display the geolocation of
test inspection / location |
Yes |
GPS |
Yes |
Data Interface |
Bluetooth |
Camera |
Yes |
Record Entry |
Through
Integrated/Touch Screen |
Availability of audible beeper for over range,
low battery etc. |
Yes |
If yes, Capable to capture the clear image of
test target |
Yes |
Record Data Downloadable to PC |
Yes |
Minimum Record Fields |
Full
Information as per the user's requirement such as Driver Name, Vehicle
number, inspector name, test report with time, date, geo-location, instrument
id etc. |
Environmental / Certification |
Name of the Lab and Address |
AERF |
Conformity to Dry Heat test at 50 degree C for
16 hours as per IS :9000 latest |
Yes |
Test Report Number and Date |
ATCC2/775
17-07-2021 |
Conformity to Damp heat at 40 degree C - 95%
RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest |
Yes |
Conformity to Cold test at - 5 / -10 / - 15 /
-20 degree C (as applicable) for 4 hours as per IS: 9000 latest |
Yes |
Availability of Test Reports from Central Govt
/ NABL approved / ILAC accredited Lab to prove conformity to the
specification |
Yes |
Operating Conditions |
Maximum
Operating Temperature |
50
degrees Celsius |
Minimum Operating Temperature |
-10
degree Celsius |
Relative Humidity Non-Condensing (%) |
80 |
Physical |
Size (mm x
mm x mm) |
180x75x35 |
Weight |
430
grams |
Printer |
Printer
consists of Inbuilt Rechargeable Battery, Paper for offence printouts,
Charger |
Yes |
Printer |
With |
"Minimum number of printouts that can be
taken with single charge of the printer battery (Hint: - Minimum 60 prints, if
'With Printer' May indicate '0' if not applicable)" |
100 |
Minimum number of printouts that can be taken
with the paper available with the Printer |
30 |
Type of Printer |
Internal
Thermal Printer |
BIS Registration number for Printer under CRS
of Meaty |
R-93005070 |
Print Resolution (dpi) |
300 |
Printer Battery is BIS Approved |
Yes |
BIS Registration number for Printer Battery
under CRS of Meaty |
R-910071 |
Statutory
Requirements |
If yes, the
equipment meets the requirements of the applicable latest Central Motor
Vehicle Rules and all Govt notifications |
Yes |
Immunity to RF interface, meets requirement as
per EN:5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent |
Yes |
The equipment can be used as an evidential
instrument for Traffic Law Enforcement, the instrument is handheld, portable
and easy to operate |
Yes |
RoHS
Compliant |
Yes |
Sensor Technology |
Electrochemical
- Fuel Cell (alcohol specific) |
Sampling modes |
Both
Active and Passive |
Time required for re-calibration |
12
months |
Sampling Error Detection |
Alarm
on wrong sampling |
Barometric Pressure Range (hpa or millibar) |
800
millibar |
Drift of the breath analyzer in 6 months
period (mg / 100 ml BAC) |
1 |
Analytical Response Time (At '0' level of
Alcohol) |
2
second |
Warm up Time (after putting on) |
3
second |
Easily replaceable mouthpiece with Sputum Trap |
Yes |
Shelf Life of Fuel Cell |
3
years |
Sample Taking Duration |
2
second |
Sampling Method |
Deep
Lung Exhalation Method |
Measuring Range [mg / 100 ml BAC (Blood
Alcohol Concentration)] |
0
to 500 |
Accuracy |
+/-
5 % or better |
Analytical Response Time for positive result |
6
second |
The Equipment meet RFI requirement as per
EN:5008-1/1992(emission) and EN 50082-1:1997(immunity) or equivalent
requirements |
Yes |
Recovery Time at (1/2) mg/later |
3 second |