LIGHT SOURCE
Light Source |
Deuterium Lamp,Tungsten Halogen Lamp |
Diffraction Grating (lines/mm) |
1200 |
Switching of Light Source |
Automatic |
Wavelength Setting And Scanning |
Automatic |
TYPE
Type of Spectrophotometer |
UV - VISIBLE |
Type of Optical System |
Single Beam |
Monochromator Type |
Holographic Grating |
Detector Type |
Photodiode |
Spectral Bandwidth Type |
Fixed Bandwidth |
OPTICAL PERFORMANCE
Source Wavelength - Minimum |
190 nanometer |
Source Wavelength - Maximum |
1000 nanometer |
Resolution |
0.5 nanometer |
Wavelength Accuracy (+/-) |
0.5 nanometer |
Bandwidth (nm) |
2.0 |
If variable band width, Specify the
incremental step value(mm) |
NA |
Scanning Speed (nm/min) |
3000 |
Focal length (mm) |
0 to 49 |
Photometric measurement modes |
Transmittance,Absorbance,Concentration
(Wavelength, time) |
Photometric Absorbance (Max) (Abs) (+/-) |
0.3 |
Photometric Absorbance Accuracy (Max) (+/-) |
0.5 |
Photometric Transmittance (Max) (+/-) |
100 percent |
Photometric Transmittance Accuracy (Max)
(+/-) |
0.5 percent |
Photometric Reflectance (Max) (+/-) |
0 percent |
Photometric Reflectance Accuracy (Max) (+/-) |
0 percent |
Stray Light Correction |
Automatic |
Baseline Correction |
Automatic |
Display |
In-built display |
Display type |
LCD with Backlight |
Display Size |
3 inch |
Test result printing |
Through external printer |
If inbuilt printer, Type of printer |
N/A |
Suitable software for connecting PC &
Printer |
Yes |
Connectivity |
USB |
Internal storage(GB) |
4 |
Sample switching/selection |
Manual |
Capacity of Sample holder / Sample Carousel |
4 |
Mximum Path Length of sample |
100 millimeter |
Number of Cuvettes supplied-inclusive in the
scope of supply |
6 |
Power Supply |
230 V ± 10, 50 Hz |
Any other features/accesories covered in
scope of supply |
Software, maunal |
Spares and Consumables inclusive in the
scope of supply |
Yes |
List of Items and Quantity of each item
included in the offer |
Cover |
OPERATING CONDITIONS
Minimum Operating Temperature |
10 degree Celsius |
Maximum Operating Temperature |
35 degree Celsius |
Operating Humidity (RH) (%) at 40 degree C |
80 percent |
Availability of UL/CE Certification as per
EN 61010-1:2010 Safety requirements for electrical equipment for measurement,
control, and laboratory use General requirements |
No |
Conformance to EMC/EMI as per EN
61326-1:2013 Electrical equipment for measurement, control and laboratory use |
No |
Availability of Test Reports from Central
Govt / NABL approved / ILAC acredited lab to prove conformity to the
specification |
No |
If yes test report to furnished,to the buyer
on demand |
N/A |
Test Report number and date |
N/A |
Name and address of the Lab |
N/A |